Basic commissioning
p50171
p50172
p50180
p50181
p50303
p50304
p50305
p50306
Final confirmation
Confirm the parameters you have entered to save them. Once you have selected "Continue"
and activated your entries with <F5>, the parameters you entered will be permanently saved
and the calculations required for closed-loop control carried out.
Optimization runs
Perform the optimization runs one after the other:
To navigate through the selection fields, choose <F2> or <F3>.
To activate a selection, choose <F5>.
p50051 = 23
p50051 = 24
p50051 = 25
p50051 = 26
p50051 = 27
p50051 = 28
p50051 = 29
See Chapter "Drive optimization" for more details
If an optimization run is not carried out, the motor control uses the motor characteristic
values calculated from the rating plate data rather than the measured values.
WARNING
During optimization runs, the drive initiates motor movements that can reach the maximum
motor speed.
The EMERGENCY OFF functions must function at the commissioning.
To protect man and machines, the relevant safety regulations must be observed.
SINAMICS DCM DC Converter
Operating Instructions, 02.2015, A5E34763375/RS-AA/001
8.3 Commissioning using the AOP30 operator panel
Current limit, torque direction I
Current limit, torque direction II
Torque limit I
Torque limit II
Ramp-up time 1
Ramp-down time 1
Initial rounding 1
Final rounding 1
Optimization of the armature current control for induction load
Optimization of the field current control
Optimization of the armature current control
Optimization of the speed control
Optimization of the EMF control (incl. field characteristic recording)
Recording of the friction characteristic
Optimization of the speed control for drives with a mechanical system capa-
ble of oscillation
ac.maher.co.ir
Commissioning
271