Descriptions of functions
10.3 Communication according to PROFIdrive
Application class 2 (standard drive with technology function)
The total process is subdivided into a number of small subprocesses and distributed among
the drives. This means that the automation functions no longer reside exclusively in the
central automation device but are also distributed in the drive controllers.
Of course, this distribution assumes that communication is possible in every direction, i.e.
also cross-communication between the technology functions of the individual drive
controllers. Specific applications include setpoint cascades, winding drives, and speed
synchronization applications for continuous processes with a continuous web.
Figure 10-2
Selection of telegrams as a function of the application class
The telegrams listed in the table below (see also Chapter Telegrams and process data
(Page 385)) can be used in the following application classes:
Table 10- 6
Selection of telegrams as a function of the application class
Telegram
Description
(p0922 = x)
1
Speed setpoint, 16-bit
2
Speed setpoint, 32-bit
3
Speed setpoint, 32-bit with 1 position encoder
4
Speed setpoint, 32-bit with 2 position encoders
20
Speed setpoint, 16-bit VIK-NAMUR
220
Speed setpoint, 32-bit for metal industry
352
Speed setpoint, 16-bit, PCS7
999
Free telegrams
384
Application class 2
ac.maher.co.ir
Class 1
SINAMICS DCM DC Converter
Operating Instructions, 02.2015, A5E34763375/RS-AA/001
Class 2
x
x
x
x
x
x
x
x
x
x
x
x