Descriptions of functions
10.3 Communication according to PROFIdrive
STW2_BM (control word 2, metal industry)
See function diagram [2426].
Table 10- 11 Description of STW1_BM (control word 1, metal industry)
Bit
Meaning
0
Command data set selection CDS bit 0
1
Reserved
2
Drive data set selection, CDS bit 0
3
Drive data set selection, CDS bit 1
4
Reserved
5
1 = Bypass ramp-function generator
6
Reserved
7
1 = Speed controller integration value set
8
1 = Enable droop
9
1 = Enable speed controller
10
Reserved
1)
11
0 = Speed-controlled mode
1 = Torque-controlled mode
12
Reserved
1)
13
Reserved
1)
14
Reserved
1)
15
Controller sign-of-life toggle bit
Interconnection is not disabled.
1)
NSET_A (speed setpoint A (16-bit))
● Speed setpoint with a 16-bit resolution with sign bit.
● Bit 15 determines the sign of the setpoint:
– Bit = 0 → Positive setpoint
– Bit = 1 → Negative setpoint
● The speed is normalized via p2000.
NSET_A = 4000 hex or 16384 dec ≐ speed in p2000
392
1)
1)
1)
ac.maher.co.ir
Interconnection parameter
p0810 = r2093.0
-
p0820[0] = r2093.2
p0821[0] = r2093.3
-
p50641[0] = r2093.5
-
p50695[0] = r2093.7
p50684[0] = r2093.8
p0856[0] = r2093.9
-
p50687[0] = r2093.11
-
-
-
p2081[15] = r2093.15