7.4.3.3
X520, X530 digital inputs
Table 7- 27
Screw terminal X520
Terminal
1
2
3
4
5
6
Table 7- 28
Screw terminal X530
Terminal
1
2
3
4
5
6
DI: Digital input; M: Electronics ground; M1, M2: Ground reference
1)
Note
An open input is interpreted as "low".
Terminal M1 or M2 must be connected in order that digital inputs (DI) can function.
This is carried out by:
1) Providing the ground reference of the digital inputs, or
2) A jumper to M (caution! This removes the electrical isolation for these digital inputs).
SINAMICS DCM DC Converter
Operating Instructions, 02.2015, A5E34763375/RS-AA/001
Designation
1)
DI 0
DI 1
DI 2
DI 3
M1
M
Designation
1)
DI 4
DI 5
DI 6
DI 7
M2
M
ac.maher.co.ir
Additional system components
7.4 Terminal Module TM31
Technical specifications
Voltage: - 3 to +30 V
Typical power consumption: 10 mA at 24 VDC
Input delay:
- For "0" to "1": typ. 50 µs max. 100 µs
- For "1" to "0": typ. 130 µs max. 150 µs
Electrical isolation: Reference potential is
Terminal M1
Level (including ripple)
High level: 15 to 30 V
Low level: -3 to +5 V
Technical specifications
Voltage: - 3 to +30 V
Typical power consumption: 10 mA at 24 VDC
Input delay:
- For "0" to "1": typ. 50 µs max. 100 µs
- For "1" to "0": typ. 130 µs max. 150 µs
Electrical isolation: Reference potential is
Terminal M2
Level (including ripple)
High level: 15 to 30 V
Low level: -3 to +5 V