9.3.11
Assigning parameters to make AOP30 time-of-day master
The AOP30 contains an integrated real-time clock. The SINAMICS DCM system time can be
synchronized with this real-time clock.
Activate this function:
● On the AOP30 in the
command activate to
The current time in the AOP30 is then written into the drive.
In the display for faults and alarms, the time stamp is now displayed in the format YY-MM-
DD hh:mm in real-time. The time stamp mode and the current time can be read from the
parameters p3100, p3102 and p3103. For details, please see the SINAMICS DCM List
Manual.
The current time is resynchronized at each power-up. (The AOP30 must be switched on
together with the drive). During uninterrupted duty, a synchronization takes place every day
at 02:00.
SINAMICS DCM DC Converter
Operating Instructions, 02.2015, A5E34763375/RS-AA/001
9.3 Controlling via the AOP30 operator panel
"Menu/Commissioning/Service/AOP settings/Date and Time"
"AOP sets clock in SINAMICS"