Descriptions of functions
10.16 Switch-on command for holding or operational brake
Figure 10-66 Operational brake (p50080 = 2), brake-release time (p50087) positive
Footnotes for the two figures above
<1>
Mechanical deceleration of drive by means of operational brake
<2>
Drive coasting down; "Close holding brake" first applied when n < nmin
<3>
Time for brake to be released before motor applies torque (p50087 positive)
<5>
Time for brake to be closed, during which motor continues to apply torque (p50088)
Figure 10-67 Holding brake (p50080 = 1), brake-release time (p50087) positive
540