Download Print this page

Siemens SINAMICS DCM Manual page 426

Dc converter
Hide thumbs Also See for SINAMICS DCM:

Advertisement

1st parameter address ... 4th parameter address
● Attribute:
10 hex → The parameter values are to be written.
● Number of elements
01 hex → One array element is written.
● Parameter number
Specifies the number of the parameter to be written (p1055, p1056, p50436).
● Subindex:
0 dec → ID of the first array element.
1st parameter value ... 4th parameter value
● Format:
07 hex → Data type, unsigned32
08 hex → Data type, floating point
● Number of values:
01 hex → A value is written to each parameter in the specified format.
● Value:
BICO input parameter: Enter signal source
Adjustable parameter: Enter value
2. Initiate parameter request
3. Evaluate parameter response
Parameter response
Response header Request reference mirrored = 40 hex
SINAMICS DCM DC Converter
Operating Instructions, 02.2015, A5E34763375/RS-AA/001
Axis mirrored = 02 hex
ac.maher.co.ir
Descriptions of functions
10.3 Communication according to PROFIdrive
Response ID = 02 hex
Number of parameters =
04 hex
Offset
0
2
427