Product Counter Settings; Figure 86 Product Counter Settings - Reset - Leibinger JET3 Series Operating Manual

Hide thumbs Also See for JET3 Series:
Table of Contents

Advertisement

Group 8

7.5.2.2 Product counter settings

Proceeding (see Figure 86 and Figure 87)
 Press the option <Product Counter Settings> (2).
 The window <Product Counter Settings> is displayed. Depending on how many
product counters are defined (1 or 2) (6) you can see 1 or two tabs.
1. Reset counter (Figure 86)
 Press the button <Reset> (4) to reset the counter or cancel the process with the
button <Cancel> (6).
 If there are 2 product counters defined each of them has to be reset separately.
Note: The will be no further confirmation prompt.
 The value „0" is now displayed in the status field <Production Counter> of the
main dialog box.
Figure 86
Product Counter Settings - Reset
Select Product Counter Settings / 1 or 2 product counters
Settings for 1 product counter
2
3
Reset one product counter
4
To reset the product counter push the
<Reset> button. The dialog box will close
and the product counter is set to 0.
Status field
1 – Options <Product Counter>
2 – Option <Product Counter Settings>
3 – Option <2. Product Counter> with indicator
JET3 Series
Job Editor
Settings for 2 product counters
1
2
3
Reset two product counters
4
Each product counter has to be reset
separately. Pushing the <Reset> button
will close the dialog box and set the
respective product counter to 0.
Results
4 – <Reset> Button
5 – <Set> Button
6 – <Cancel> Button
Page 185
1
5
6
Status field
Release 2.02