Leibinger JET3 Series Operating Manual page 251

Hide thumbs Also See for JET3 Series:
Table of Contents

Advertisement

Group 8
Example In this example lengths specifications are printed on a cable (for details see
<Meter-Go-function>). In addition the word Leibinger shall be printed
together with each third printout. See Picture 1 for details.
Picture 1 – Example cable print: the Leibinger logo together with each
The printout of the length
specifications are controlled by the
PrintGo signals. The printout of the
Leibinger logo is controlled by the
value of the counter that is assigned to
the Leibinger text object.
Picture 2 shows the timing diagram.
For this print job are several settings
required.
Settings for the PrintGo parameters
The PrintGo parameters are the same
for all objects printed. The PrintGo
signals (from the external measuring
system) and the StrokeGo signals
(from the external encoder) are used
to control the printout.
Relevant settings are marked in
Picture 3.
JET3 Series
Job Editor
third meter printout
Picture 2 – Timing diagram for
the periodically
repeating object
Picture 3 – PrintGo settings for all
printed objects
Page 249
Release 2.02

Advertisement

Table of Contents
loading

This manual is also suitable for:

Jet3 upJet3up proJet3up miJet3up piJet3up ep

Table of Contents