5.5.3.2 Mechanical installation

For the mechanical installation of the shaft encoder you have to pay
attention in any case that the encoder is protected against axial and radial
strain during the mounting and the continuous operation. For this a rubber
gaiter or a plastic coupling is used.
If the conditions allow it, the shaft encoder can be also adapted to a production line with a
friction wheel.
Risk of injury!
The shaft encoder has to be installed or mounted that no risks of injury
can occur!

5.5.4 Interface X4 - Digital inputs

19 inputs for special functions are available whereof the connections of 6 inputs can be
freely selected.
Plug assignment:
JET3 Series
Transport/Start up
ATTENTION
ATTENTION
Pin connection:
Pin Designation
1
+Reset Counter
2
+Increment Counter
3
+Jobselect 0
4
+Jobselect 2
5
+Jobselect 4
6
+Jobselect 6
7
+Jobselect 8
8
GND Jobselect 0-9
9
+Input 0
10
+Input 2
11
+Input 4
12
+Power ON
13
GND 24V
Pin Designation
+24V
(1)
14
15
GND Reset Counter /
Increment Counter
16
+Jobselect 1
17
+Jobselect 3
18
+Jobselect 5
19
+Jobselect 7
20
+Jobselect 9
21
GND Input 0-5
22
+Input 1
23
+Input 3
24
+Input 5
25
GND Power On