Group 8
7.4.4
Special functions and tools
Under the tab <Special Functions/Tools> the following functions are available:
Pressureless
Constant Bleed
Deplete Ink
Deplete Solvent
Calc Delay Time
7.4.4.1 Constant bleed
The function constant bleeding is only activated or functional under the
following device conditions:
Ink suction is turned on
Nozzle is closed
Head cover is removed
By pressing the button <Constant Bleed> (1) the constant bleeding is started. During the
process the message „Constant Bleed" (2) is displayed. The bleeding can be canceled
any time by pressing on the button <Stop> (3). During this process the visco pump is
activated for 3 sec. every minute to ensure a purging of the pump.
With the button <Add Solv> (4) you can add only solvent. This function provides specially
filling operations to bleed e.g. the solvent tube or to set the viscosity of the ink faster to a
lower value.
By adding solvent the ink can be diluted too strong. Therefore this function
should only be carried out by qualified personnel.
JET3 Series
Job Editor
Calc last PG Drops
Mix only Ink
Mix only Solvent
Fill up Routine
Ignore error messages and warnings
ATTENTION
ATTENTION
Page 167
Release 2.02