Hydraulic-/Printhead - And Special Functions - Leibinger JET3 Series Operating Manual

Hide thumbs Also See for JET3 Series:
Table of Contents

Advertisement

Page 162
The dialog box allows testing the inputs and outputs of the LEIBINGER Printer for
troubleshooting without additional tools.
While the dialog box <I/O-signals> is open in- and output signals do not affect the <I/O
Settings>.
Outputs can be activated/deactivated by a click on the respective button.
Active in-/outputs are displayed by a green status display.
Closing the dialog box will reset all settings and counters.
7.4.2
Hydraulic-/Printhead – and special functions
This work must only be carried out by trained personnel or by Leibinger
service technicians!
By pressing one of the options <Printhead> (2) or <Hydraulic> (4) or with the
respective direct buttons [Shortcuts] (3) or (5) you can open the dialog box
„Hydraulic/Printhead Test" (6).
This dialog box provides the verification of hydraulic components, activation or
deactivation and setting of print head functions as well as the processing of special
functions. All changes have only a temporary effect, that means as long as the dialog
box is open.
The selection of a tab happens by clicking on the accordant tab (7).
Note: The proceeding corresponds to the Windows™-standard procedure.
By pressing the button <Fast shutdown> (9) the Printer is turned off immediately,
without carrying out further actions (e.g. closing the nozzle).
The button <Close> (8) closes the dialog box.
By closing the dialog box all changes are reset to the normal/fully automatic
operating condition!
When the dialog box is closed a confirmation prompt (10) pops up.
Release 2.02
Job Editor
SERVICE WORK AND SPECIAL FUNCTIONS
INFORMATION
Group 8
JET3 Series

Advertisement

Table of Contents
loading

This manual is also suitable for:

Jet3 upJet3up proJet3up miJet3up piJet3up ep

Table of Contents