8.5.2.6.4 Sensor monitoring – PrintGo length
With the <PrintGo length > function the length of the product on which to be printed is
monitored.
If the measured length is out of tolerance an error message pops up.
The function requires the length of the product and the tolerance as parameters.
The tolerance set is always a +/- tolerance!

Figure 149 PrintGo length - Settings

1 – <PrintGo length> activation
2 – Input field <PrintGo length>
3 – Input field <PrintGo length tolerance>

Figure 150 PrintGo length - Example

1
PrintGo length
PrintGo tolerance
2
Product in the wrong position
With the <PrintGo length> function the PrintGo sensor does not only control the print
start but is used also for the measurement of the length of the product.
If the product is in the wrong printing position the measured length will be out of
tolerance and an error message will pop up.