Meter Go Function; Figure 153 Parameter Settings Meter Go Function - Leibinger JET3 Series Operating Manual

Hide thumbs Also See for JET3 Series:
Table of Contents

Advertisement

Page 272

8.5.2.10 Meter Go function

The Meter Go function is a special function for printing length specifications on cables,
pipes etc. The function results from several parameter settings.
With these settings one can ensure that the meter counter carries on counting even if
there are no printouts. The counter works independent from the printout as long as there
are encoder signals.
External encoder signals are required for the position and speed measuring. In addition
there should be an external PrintGo signal provided in exactly the same distance as the
required printout of the length specifications (e.g. after each meter).
It is not recommended to use the Meter-Go function with the internal PrintGo signal.
To use the internal PrintGo signal you would have to specify the cable speed. Even the
smallest deviation would sum up with each printout and this would lead to a significant
deviation between the printed length specifications and the current length of the cable.
Figure 153
Parameter settings Meter Go function
Counter object settings
The crucial setting for the Meter Go
function within the parameters for the
counter object is the setting for the
<Counter Increment>. This value has
to be set to with PrintGo. Please see
example for details.
Release 2.02
Job Editor
Job settings
For printing length specifications on
cables, pipes etc. use the parameters
shown above. These settings are true
while using an external PrintGo signal.
Please see example for details.