5.4.2 Fill reservoir tank - Step 2

To avoid damages of the device during the transportation the reservoir tanks should be
evacuated and have to be filled before the initial operation.
Danger of explosion!
 Discharge before filling the device with consumables.
The operator should discharge by touching the cabinet of the printer.
Additionally it is highly recommended wearing ESD-shoes.
Dangerous material in the machine!
 Danger of serious damage through burns, skin irriation and poisoning!
 Protective equipment is necessary! Read the safety data sheets and
The reservoir tanks for ink and solvent are installed beneath the cover flap of the refill unit.
The two reservoir tanks are monitored by level sensors. They are always unpressurized and
can be opened in every device condition.
The reservoir tanks and the sealing cap are color-coded and labelled to avoid any mistakes
in filling. Additionally the sealing caps are marked with the ink-no. or solvent-no. which are
admissible for the device. For correct handling the LEIBINGER re-filling system allows an
odor- and splash free refilling of the consumables.
Attention
Use only genuine Leibinger solvent and ink that comes with a TAG on the
refill bottle!
The printers are supplied with a TAG Reader. For refills of solvent or ink make
sure that only genuine LEIBINGER ink and solvent is used. Only then the refill
bottles will have TAG. The TAG has to be registered by the TAG reader of the
printer before filling up the reservoir tanks!
Please see chapter 10.1.2 TAG-reader for details about the TAG reader!