Group 5
Basic data/Recommended working conditions:
Signal
PrintGo
For
PNP-sensors
PrintGo
For
NPN-sensors
PrintGo Gate
For
PNP-sensors
You will find a circuit diagram of the interface in the appendix of this
manual!
(1)
All 24V inputs which are designated with (1) are protected by a self-reset fuse with 700 mA.
JET3 Series
Transport/Start up
Parameter
Input level High
Input level Low
Minimum pulse duration
Input resistance
Input level High
Input level Low
Minimum pulse duration
Input resistance
Input level High
Input level Low
Minimum pulse duration
Input resistance
INFORMATION
Value
15 up to 30V
-3,5V up to 3,5V (or high resistance)
100µS
6,8 kOhm
20 up to 28V (or high resistance)
-6V up to 9V
100µS
6,8kOhm
15 up to 30V
-3,5V up to 3,5V (or high resistance)
100µS
6,8 kOhm
Page 55
Release 2.02