Group 4

4.2 Electrical connection values

Input voltage (voltage range):
Current consumption:
Power consumption:

4.3 Ambient conditions

Temperature range:
Relative humidity:

4.4 Interfaces, Inputs, Outputs

Product sensor input:
Incremental encoder input:
Inputs:
Outputs:
Interfaces:

4.5 Performance parameter

Printing capacity:
Printing speed:
JET3 Series
Accident prevention
100 - 240 V AC, 50-60 Hz
max. 0,56 A (peak) at 100 V AC
max. 0,25 A (peak) at 240 V AC
typ. 20 W at 100 V AC
typ. 20 W at 240 V AC
+ 5° C to + 45° C (no rapid change of temperature)
max. 90 % relative humidity (non-condensating)
NPN/PNP 24V
TTL 5V, HTL 24V, RS422 5V
6 digitals, free selectable
10 inputs for ext. job selection
8 digitals, e.g. for alarm, re-filling, etc.
Ethernet (Industry standard M12D)
Serial Interface (V24/RS232) up to 115.200 Baud
USB
Character height: approx.
 min.: 0,8 mm
 max.:16 mm
Depending on font, distance of head, nozzle diameter, ink,
product surface and type of print head
Up to 3200 characters/sec.
Up to 6,6 m/sec (10 cpi)
Page 33