Group 8

7.3.3.1 Digital Inputs

With the tab <Inputs> you can assign functions to the available inputs.
E.g.: Input 1 (X4.9 (of the Pin No. 9 of interface X4)) should be assigned the function
"Counter reset".
Proceeding:
 Select the <Inputs>tab (2)
 Press on the arrow key of the drop-down list of the input 1 [X4.9] (3). The drop-
down list provides a list of functions for selection.
 Now select the required event/signal.
Please see chapter 5.5.4 Interface X4 - Digital inputs for detailed
information about the digital inputs.
Figure 62
Assign functions to digital inputs
2
4
1 – Dialog box <I/O Settings>
2 – Tab <Inputs>
JET3 Series
Job Editor
INFORMATION
3 – Drop-down list <X4.9>
4 – Pin designation