Usb-Connection - Leibinger JET3 Series Operating Manual

Hide thumbs Also See for JET3 Series:
Table of Contents

Advertisement

Group 5
5.5.7

USB-Connection

The USB-connection can be used for all common USB-devices as e.g. mouses,
keyboards or USB-sticks. All data can be exchanged comfortable and simply by the USB-
connection. Software updates, exchange of variable printing data or memory expansions
can be carried out simply with the USB-stick.
Shoot & print option
With an optional bar code scanner connected to the USB port it is possible to emulate
keyboard inputs with barcodes in order to avoid typing errors.
Plug assignment:
JET3 Series
Transport/Start up
Commands read from bar codes to load and
execute pre-installed print jobs.
If the bar code scanner is connected to the
USB port it is used to emulate keyboard
inputs.
With a bar code scanner connected to the
RS 232 interface of the printer there are
further options available. Please see the
following chapters for details:
8.7.5 Extern Text
Pin connection:
Pin
Designation
1
+V (+5V)
2
Data -
Pin
Designation
3
Data +
4
GND