Page 178

7.4.8 Error Format

Attention
Deactivating error messages pose a safety risk
Only LEIBINGER service staff or service staff trained by LEIBINGER are
allowed to deactivate error messages.
Deactivating error messages is allowed only for service purposes.
With the function <Error Format> it is possible to deactivate certain erro messages.
This function is meant only for service purposes!
The option <Erro Format> (2) opens the dialog box <Error Message Settings> (3). The
dialog box shows the following parameters:
 Visco Erro(4)
 Fill State Error (5)
 Hydraulic Leak Error (6)
With the <OK> button (8) alle chages are saved and the dialog box is closed. The
<Cancel> button (9) discards all changes and closes the dialog box.
Figure 81
Dialog box Error Message Settings
3
4
5
6
8
1 – Drop-down menu <Service functions>
2 – Option <Error Format>
3 – Dialog box <Erro Message Setting>
4 – Option <Visco Error>
Approach
Release 2.02
Job Editor
5 – Option <Fill State Error>
6 – Option <Hydraulic Leak Error>
7 – Deactivated error messages
8 – <OK> Button
9 – <Abbrechen> Button
Group 8
1
2
7
9