Page 38
5.3 Installation
For adaption to the production line several works have to be carried out and operating
parameters have to be set before start of operation.
5.3.1
Mains supply
The device does not have a mains switch and should be only connected
to an easy accessible socket close to the installation location!
The printer can be connected to AC voltage 100 - 240 V AC, 50 – 60 Hz with an appropriate
plug. The socket should be provided with a clear designation (e.g.: Printer).
After connecting to the mains power supply the initialization of the device will be carried out
automatically. After this process the printer is ready for operation.
You will find further information regarding the initialization in the chapter
6.5.2 First initialization of the device
5.3.2 Grounding - Potential equalization
Grounding (Potential equalization)!
In case of a non existing grounding or that the grounding of the
These dangers or demolitions can happen for example because of
Especially for countries without existing protected earth connection, there is a special
grounding point located at the side of the printer.
This threaded socket must be connected to ground if there is no ground pin in the mains
socket/plug.The threaded case is sealed inwards and thus IP 65 conform. With a screw and
a ring terminal (cable lug) the grounding can be fixed easily.
Release 2.02
Transport/Start up
WARNING – MAINS SUPPLY
INFORMATION
WARNING
printer is not carried out properly, this could cause serious injury or
death and it can also cause malfunctions or damages at the printer!
electrostatic discharge (ESD) or potential difference!
Group 5
JET3 Series