Interface X3 - Digital Outputs - Leibinger JET3 Series Operating Manual

Hide thumbs Also See for JET3 Series:
Table of Contents

Advertisement

Group 5

5.5.5 Interface X3 - Digital outputs

8 outputs which can be freely selected are available for special functions. The outputs 1-
3 are predefined as a standard and should be not changed.
 Output 1 = Print stop error
 Output 2 = Refill warning
Plug assignment:
Specifications Output 1-8:
Parameter
Driver type
Output current
Max. switching frequency
Max. delay time
Turn on resistance
Features
The function allocations of the outputs is carried out with the software of
the printer in the menu
Settings  I/O-Settings  Outputs.
You will find a circuit diagram of the interface in the manual appendix!
(1)
All 24V outputs which are designated with (1) are protected by a self-reset fuse with 700mA, that
means the sum of all output currents which are supplied of this 24V should not exceed 700mA.
(2)
Depending on the set function.
JET3 Series
Transport/Start up
Pin connection:
Pin Designation
1
Output 1
2
Output 2
3
Output 3
4
Output 4
+24V
(1)
5
6
Mirror (JETMotion)
7
Reserved
8
GND
Reserved = Do not connect
Value
24V high side driver
ON = +24V
OFF = high resistance
max. 700mA/output
max. 700 mA totally
2 kHz
(2)
100µs
max. 0,28 Ohm
 Short-circuit-proof
 Overcurrent- and excess temperature –proof
INFORMATION
 Output 3 = Ready to print
Pin Designation
9
Output 5
10
Output 6
11
Output 7
12
Output 8
13
IP65 fail
14
Reserved
15
GND
(1)
Page 59
Release 2.02

Advertisement

Table of Contents
loading

This manual is also suitable for:

Jet3 upJet3up proJet3up miJet3up piJet3up ep

Table of Contents