Create New Job Lists - Example : Extern Jobselect With Distances - Leibinger JET3 Series Operating Manual

Hide thumbs Also See for JET3 Series:
Table of Contents

Advertisement

Page 106
7.2.5.2 Create new job lists – Example : Extern Jobselect with distances
Task:
This example is based on the last example (see 7.2.5.1).
Three different print jobs shall be printed. The print-out shall not be carried out in a fixed
order but on the basis of direct addressing each print job. The addresses of the print jobs
shall be 1, 5 and 7 and the print order 1-7-5-5-1. The job list is the same as for Example
1 but the parameters of the single print jobs are different.
For this example the following parameters were added to each print job:
Print job
Print job
address
1
JL-Job1
5
JL-Job2
7
JL-Job3
Presets:
The presets for this example are the same as for example 1.
Settings:
The joblist settings are the same as for example 1.
Approach:
The numbers in brackets refer to the pictures in Figure 37.
1. Open the job list with the <Load Joblist to print> (1-3).
2. Apply the address of the print job at the first position of the job list to the X4
connector (decimal=1; 10-bit binary=0000000001) (4).
3. With the next <PrintGo> signal the addressed print job will be printed. For this
print job the <PrintGo delay> is set to 0 mm. Therefore the printout will start
directly with the <PrintGo> signal (6). <PrintGo repetition> is set to two and the
<PrintGo distance> is set to 60 mm. Therefore there will be a total of three
printouts (6) and the distances between the first dots of each printout/repetition
will be 60 mm (7).
4. Apply the address of the print job at the seventh position of the job list to the X4
connector (decimal=7; 10-bit binary=0000000111) (13) (8).
5. With the next <PrintGo> signal the addressed print job will be printed. For this
print job the <PrintGo delay> is set to 30 mm. Therefore the printout will start 30
mm after the position where the <PrintGo> signal occurred (9). <PrintGo
repetition> is set to 1 and the <PrintGo distance> is set to 70 mm. Therefore
there will be a total of two print (10) outs and the distances between the first dots
of each printout/repetition will be 70 mm (11).
6. Apply the address of the print job at the fifth position of the job list to the X4
connector (decimal=5; 10-bit binary=0000000101 (12).
Release 2.02
Job Editor
PrintGo
PrintGo
delay [mm]
distance [mm]
0
20
30
PrintGo
repetition
60
2
50
3
70
1
Group 8
endless
no
no
no
JET3 Series

Advertisement

Table of Contents
loading

This manual is also suitable for:

Jet3 upJet3up proJet3up miJet3up piJet3up ep

Table of Contents