Group 8
Functional descriptions
Pressure (4)
This is the setpoint of the pressure of the hydraulic circuit in [mbar].
Suction pump (5)
The suction pump works at partload. The partload value is defined percentage of the full
load.
Visco correction (6)
The printer is supplied with a factory calibrated viscometer. The <Visco correction> is
used for such calibrating purposes.
Fall time (7)
This is the setpoint for the viscosity of the current ink.
Nozzle (8)
The size of the nozzle of the printer in [µm].
Oscillator Voltage (9)
The setpoint of the oscillator voltage. This value is only adjustable through a special
service access.
Ink number (10)
The number of the currently used ink.
Solvent number (11)
The number of the solvent suitable for the current ink. This value is set automatically
dependent on the current ink.
Frequency (12)
The setpoint of the frequency of the oscillator.
Indicators for current values (13)
The pressure within the hydraulic circuit, the power consumption of the suction pump and
the falltime (viscosity) are constantly measured and indicated.
Spin buttons for settings (14)
All setpoints can be changed by using the spin buttons of the respective input fields.
Drop-down list <Ink number> (15)
The drop-down list shows the available inks.
Drop-down list <Frequencies> (16)
The drop-down list shows the available frequencies.