Page 276
Information
Please see also chapter 12.3 Encoder guidelines and "hot-plugging" of
external devices for details about encoders.

8.5.3.1 Encoder source - StrokeGo-source

There are three options in order to define the <StrokeGo> source:
 Internal: If this function is activated, the signal is generated by the printer and needs
no external encoder device.
Additionally you have to enter the <Internal speed (intern Speed)> (3).
The internal encoder source is only recommended for constant printing
speeds.
You will find further information regarding this topic in the chapter
Internal speed
 External:
If this function is activated signals from an external encoder (e.g. incremental
encoder) are required. The encoder has to be connected to the interface X1 of the
LEIBINGER Printer.
Additionally you have to define the <Encoder/Direction> (4) and the <Resolution>
(5).
 Sensor measurement: If this function is activated the Printer printer expects 2
sensor signals in order to calculate the required printing speed. The <StrokeGo>
signals are generated on the basis of the calculated speed.
Figure 155
StrokeGo-source /Encoder source
1 – Check box <Encoder source int.>
2 – Check box <Encoder source ext.>
Release 2.02
Job Editor
ATTENTION
1
2
3
3 – Display field <Internal speed>
4 – Check box <Sensor Measurement>
Group 8
4
JET3 Series