Figure 50 Select Encoder Interface - Leibinger JET3 Series Operating Manual

Hide thumbs Also See for JET3 Series:
Table of Contents

Advertisement

Page 130
Proceeding:
 Press on the tab< Interfaces> (2) to select the tab.
 Press on the arrow key of the drop-down list <Encoder Settings> (3). The drop-down
list opens for selection.
 Now select the required interface.
 If required activate now the bounce time delay by clicking on the check box (4). An
activated delay is displayed by  in the check box.
Figure 50
Select encoder interface
1
2
4
Bounce time delay is switched off
1 –Dialog box <Basic Settings>
2 –Tab < Interfaces>
Pos. Interface
1.
RS422
2.
TTL
3.
HTL
Release 2.02
Job Editor
3 – Drop-down list <Encoder settings>
4 – Check box <Bounce time delay off>
Describtion
5V / 4 Signals (A, Ā, B, B)
5V TTL / 2 Signals (A, B)
24V / 2 Signals (A, B)
Bounce time delay is switched on
Group 8
3
JET3 Series

Advertisement

Table of Contents
loading

This manual is also suitable for:

Jet3 upJet3up proJet3up miJet3up piJet3up ep