Rep 7.5 Hcf Feed Assembly And Sensors - Xerox WorkCentre 4150 Service Manual

Hide thumbs Also See for WorkCentre 4150:
Table of Contents

Advertisement

REP 7.5 HCF Feed Assembly and Sensors

Parts List on
PL 8.10
Removal
Switch off the electricity to the machine. Disconnect the power cord from the customer
supply while performing tasks that do not need electricity. Electricity can cause death or
injury. Moving parts can cause injury.
Take care during this procedure. Sharp edges may be present that can cause injury.
Before performing this procedure, refer to General Disassembly Precautions,
1.
Remove the HCF paper tray,
Figure
3
Release the left
side catch.
4
Remove the HCF tray.
1
Fully pull out the HCF tray.
Figure 1 Paper tray removal
2.
Remove the HCF rear cover,
PL 7.45 Item
3.
Remove the tray pickup clutch and gears,
Repairs and Adjustments
REP 7.5
WARNING
WARNING
CAUTION
GP
1.
2
Raise the right side latch
to release the slide from
the rail.
4.
Figure
2.
10.
1
Remove the E-clip then
the tray pickup clutch.
4.
Disconnect CN7 from the tray PWB.
5.
Disconnect the connector on the tray elevating motor,
6.
Remove the feed head support spring and retard roll,
January 2016
4-116
WorkCentre WorkCentre 4150/4250/4260WorkCentre 4150/4250/42604150/
2
Remove the E-clip,
then the 3 gears.
Figure 2 Gear removal
PL 7.60 Item
10.
Figure
3.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Workcentre 4250Workcentre 4260Workcentre 4265