Xerox WorkCentre 5222 Service Manual page 1178

Tabloid black-and-white multifunction printer
Hide thumbs Also See for WorkCentre 5222:
Table of Contents

Advertisement

Chain-Link Content
715-642
TP_BW_Contone Suppression Level of AE
715-643
TP_BW_Contone Offset Level of AE
715-644
woTP_BW_Contone Suppression Level of AE
715-645
woTP_BW_Contone Offset Level of AE
715-646
TP_CL_Contone Removal Level of AE
715-647
TP_CL_Contone Offset Level of AE
715-648
woTP_CL_Contone Removal Level of AE
715-649
woTP_CL_Contone Offset Level of AE
715-660
2F-AE Lower Limit of Multiplied Value
715-661
2F-AE Upper Limit of Multiplied Value
715-662
Offset for 2F-AE Control
Launch Version
WorkCentre 5225, 5230
Table 2 IISS
Default
Range
Meaning
819
0~4095
0: Strength Level 0 (standard), 1: Strength Level 1, 2: Strength Level 2, 3: Strength Level 3, 4:
Strength Level 4, 5~15 and above: Strength Level 0 (standard) 0bit~3bit, Platen 4bit~7bit, CVT or
DADF 8bit~11bit, CVT or DADF 2 Sided Copy (* Used as the PreIPS EAER_DAT suppression level
as well)
0
0~4095
0: Strength Level 0 (standard), 1: Strength Level 1, 2: Strength Level 2, 3: Strength Level 3, 4:
Strength Level 4, 5~15 and above: Strength Level 0 (standard) 0bit~3bit, Platen 4bit~7bit, CVT or
DADF 8bit~11bit, CVT or DADF 2 Sided Copy
819
0~4095
0: Strength Level 0 (standard), 1: Strength Level 1, 2: Strength Level 2, 3: Strength Level 3, 4:
Strength Level 4, 5~15 and above: Strength Level 0 (standard) 0bit~3bit, Platen 4bit~7bit, CVT or
DADF 8bit~11bit, CVT or DADF 2 Sided Copy (* Used as the PreIPS EAER_DAT suppression level
as well)
0
0~4095
0: Strength Level 0 (standard), 1: Strength Level 1, 2: Strength Level 2, 3: Strength Level 3, 4:
Strength Level 4, 5~15 and above: Strength Level 0 (standard) 0bit~3bit, Platen 4bit~7bit, CVT or
DADF 8bit~11bit, CVT or DADF 2 Sided Copy
0
0~4095
0: Strength level 0 (standard), 1: Strength level 1, 2: Strength level 2, 3: Strength level 3, 4: Strength
level 4, 5or more: Strength level 0 (standard)
0 to 3 bits: Platen
4 to 7 bits: CVT or machines with DADF
8 to 11 bits: CVT or machines with DADF (duplex copy)
Coordination with TOOLS to determine the parameter selection level by adding the value for
TOOLS (level 0 to 4) and the level number of this NVM (0 to 4). When the result is level 4 or higher,
the level is 4. (Also applies to removal level of PreIPS EAER_DAT.)
0
0~4095
0: Strength level 0 (standard), 1: Strength level 1, 2: Strength level 2, 3: Strength level 3, 4: Strength
level 4, 5or more: Strength level 0 (standard)
0 to 3 bits: Platen
4 to 7 bits: CVT or machines with DADF
8 to 11 bits: CVT or machines with DADF (duplex copy)
0
0~4095
0: Strength level 0 (standard), 1: Strength level 1, 2: Strength level 2, 3: Strength level 3, 4: Strength
level 4, 5or more: Strength level 0 (standard)
0 to 3 bits: Platen
4 to 7 bits: CVT or machines with DADF
8 to 11 bits: CVT or machines with DADF (duplex copy)
Coordination with TOOLS to determine the parameter selection level by adding the value for
TOOLS (level 0 to 4) and the level number of this NVM (0 to 4). When the result is level 4 or higher,
the level is 4. (Also applies to removal level of PreIPS EAER_DAT.)
0
0~4095
0: Strength level 0 (standard), 1: Strength level 1, 2: Strength level 2, 3: Strength level 3, 4: Strength
level 4, 5or more: Strength level 0 (standard)
0 to 3 bits: Platen
4 to 7 bits: CVT or machines with DADF
8 to 11 bits: CVT or machines with DADF (duplex copy)
0
0~255
Used when calculating HAE background density. In 1/255 increments. 255=1
255
0~255
Used when calculating HAE background density. Set so that the sum of "2F-AE Upper Limit of Mul-
tiplied Value" and "2F-AE Lower Limit of Multiplied Value" is 255. In 1/255 increments. 255=1
8
0~255
Value to be added (subtracted) to the HAE background density when comparing the RAE back-
ground density and the HAE background density. With a larger value, 2-side AE is less likely to be
selected.
February, 2008
6-39
General Procedures
IIT NVM List

Advertisement

Table of Contents
loading

This manual is also suitable for:

Workcentre 5225Workcentre 5230

Table of Contents