Chain-
Link
Name
760-027
MPT for Heavyweight2 Paper - REGI LOOP TIMER 24
760-028
DUP for Heavyweight1 Paper - REGI LOOP TIMER 33
760-029
DUP for Heavyweight2 Paper - REGI LOOP TIMER 33
760-031
TRAY1 for Heavyweight4 Paper - LEAD REGI
ADJUSTMENT
760-032
TRAY2-4,HCF for Heavyweight4 Paper - LEAD
REGI ADJUSTMENT
760-033
MPT for Heavyweight4 Paper - LEAD REGI
ADJUSTMENT
760-034
DUP ALL SIZE for Heavyweight4 Paper - LEAD
REGI ADJUSTMENT
760-035
TRAY1 for Heavyweight1 Paper - REGI LOOP
TIMER
760-036
TRAY1 for Heavyweight2 Paper - REGI LOOP
TIMER
760-037
TRAY1 for Heavyweight4 Paper - REGI LOOP
TIMER
760-038
TRAY2-4,HCF for Heavyweight4 Paper - REGI
LOOP TIMER
760-039
MPT for Heavyweight4 Paper - REGI LOOP TIMER 15
760-040
DUP for Heavyweight4 Paper - REGI LOOP TIMER 24
Chain 740-xxx Chain 742-xxx Chain 764-xxx EXIT
Chain-
Link
Name
740-544
Low Noise Measure Exit2
742-098
Enable Face Down Tray#2
742-099
Enable Face Up Tray
742-100
EXIT2 Unit Type
764-005
FACE DOWN TRAY#1,#2 Offset Mode
Chain 742-xxx TRAY
Chain-Link Name
742-001
Tray1-Default width of Universal-size paper
Launch Version
WorkCentre 5225, 5230
Table 5 PH
Default
Range
1 Count
Remarks
0~66
0.435mm
Loop increases when Set Value is increased.
0~66
0.363mm
Loop increases when Set Value is increased.
0~66
0.363mm
Loop increases when Set Value is increased.
33
0~66
0.363mm
Image input is delayed when Set Value is increased.
33
0~66
0.363mm
Image input is delayed when Set Value is increased.
33
0~66
0.363mm
Image input is delayed when Set Value is increased.
33
0~66
0.363mm
Image input is delayed when Set Value is increased.
33
0~66
0.363mm
Loop increases when Set Value is increased.
33
0~66
0.363mm
Loop increases when Set Value is increased.
24
0~66
0.363mm
Loop increases when Set Value is increased.
24
0~66
0.363mm
Loop increases when Set Value is increased.
0~66
0.363mm
Loop increases when Set Value is increased.
0~66
0.363mm
Loop increases when Set Value is increased.
Table 6 EXIT
Default
Range
1 Count
Remarks
1
0~1
-
0: Not supported, 1: Supported
0
0~1
-
0: Disable Face Down Tray#2 1: Enable Face Down Tray#2 1 is taken with M0.
0
0~1
-
0: Disable Face Up Tray 1: Enable Face Up Tray
0
0~1
-
0: Type A (Enable Inverter, Disable OCT2 and FDT#2) 1: Type B (Enable Inverter and
OCT2 and FDT#2)
0
0~2
-
0: No Offset 1: Front Offset 2: Rear Offset Applies only when the Output Tray is set to
FACE DOWN TRAY#1 & #2.
Table 7 TRAY
Default
Range
1 Count
Remarks
0
0~247
1mm
0=fixed size which is detected by M/C, "90 - 247"="140mm - 297mm", "1-89"=cannot use