Xerox WorkCentre 5222 Service Manual page 1172

Tabloid black-and-white multifunction printer
Hide thumbs Also See for WorkCentre 5222:
Table of Contents

Advertisement

Chain-Link Content
710-609
Alternate Size Set9
710-610
Alternate Size Set10
710-611
Alternate Size Set11
710-612
Size-Mix Mode Size Orientation
710-613
Mixed Size Selection
Chain 715-xxx IISS
Chain-Link Content
715-017
IIT Fail Bypass
715-018
Fan Control Mode
715-020
Number of APS
715-022
Lamp Fan Fail Bypass
715-023
Lamp Fan On Time (Low Rotation)
715-024
Lamp Fan Off Time
715-025
FL Timer Set
715-026
Lamp ON Interval
715-027
Lamp ON Time
715-030
IIT Failure Part Diagnosis
715-050
Platen SS Registration Adjustment
715-051
Platen SS Reduce/Enlarge Adjustment
715-052
Platen Glass Type
715-053
Platen PRadjF
715-056
CVT FS Offset Side1-1 (139.7-148)
715-057
CVT FS Offset Rear Side2-1 (139.7~148)
715-058
CVT FS Offset Side1-2 (182-194)
715-059
CVT FS Offset Side2-2 (182-194)
715-060
CVT FS Offset Side1-3 (203.2)
715-061
CVT FS Offset Side2-3 (203.2)
715-062
CVT FS Offset Side1-4 (210)
715-063
CVT FS Offset Side2-4 (210)
Launch Version
WorkCentre 5225, 5230
Table 1 DADF
Default
Range
Meaning
0
0~2
PF1: Switches between 8x10S and 8x10.5S. No-Mix: Inch13/Inch14,0: Default,1: 8x10S,2: 8x10.5S
PF2: Switches between 8x10S and 8x10.5S. No-Mix: Inch13/Inch14,0: Default,1: 8x10S,2: 8x10.5S
0
0~2
PF1: Switches between B5L and 16KL. Size-Mix: mm,0: Default,1: B5L,2: 16KL PF2: Switches
between B5L, 16KL and 8.5x11L. Size-Mix: mm,0: Default 1: B5L,2: 16KL 3: 8.5x11L PF2 setting
range is 0~3.
0
0~3
PF1: Switches between B5S/16KS/8.5x11S. Size-Mix: mm, 0: Default, 1: B5S, 2: 16KS, 3: 8.5x11S
1
0~1
Switches between LEF and SEF.,0: LEF,1: SEF
1
0~1
Switches the size (standard size/non-standard size) to be transmitted from DADF to IISS in mixed
size mode of fax job. 0: Non-standard size mode, 1: Standard size mode
Table 2 IISS
Default
Range
Meaning
0
0~1
0: Fail Bypass Off, 1: Fail Bypass On
0
0~1
0: Normal, 1: Extended mode
1
0~1
0: 1 APS, 1: 2 APS
0
0~1
On/Off of Lamp Fan Fail Detection. 0: On, 1: Off
15
0~60
Time period to operate Lamp Fan at low rotation (value can be set in 1-minute increments)
0
0~60
Time period during which Lamp Fan stops (value can be set in 1-minute increments)
0
0~1
0: Standard FL Timer settings (30min rest/0.5sec On), 1: Condensation mode setting (Diag 715-
026, 715-027 timer settings apply)
30
1~60
Interval setting (time between Lamp OFF and Lamp ON again) (unit: min.)
1
1~60
Lamp ON time setting (unit: sec.)
0
0-65535
By writing 1, diagnosis for IIT failed part starts. The numbers of failed parts that are predicted to read
this NVM are displayed after the failed parts diagnosis ends. When Fail occurs during the failed
parts diagnosis, Fail code is recorded in this NVM and the failed parts diagnosis ends. Even when 1
is entered, the value is not actually written. When values other than 1 are entered, the values are
invalid.
100
16~184
Slow Scan Direction Regi Correction Value (0.036mm/increment), Factory Settings
50
44~56
Slow Scan Direction Regi Correction Value (0.1%/increment), Factory Settings
2
0~2
0: Platen model, 1: Belt DADF, 2: CVT, Factory Settings
120
0~240
Fast Scan Direction Regi Correction Value (Dot), VLSS=PROMVLSS+(PRadjF-120)x2, Factory Set-
tings
120
0~240
Fast Scan Direction Regi Correction Value (2dot/increment) in CVT. Factory Settings
120
0~240
Fast Scan Direction Regi Correction Value (2dot/increment) in CVT. Factory Settings
120
0~240
Fast Scan Direction Regi Correction Value (2dot/increment) in CVT. Factory Settings
120
0~240
Fast Scan Direction Regi Correction Value (2dot/increment) in CVT. Factory Settings
120
0~240
Fast Scan Direction Regi Correction Value (2dot/increment) in CVT. Factory Settings
120
0~240
Fast Scan Direction Regi Correction Value (2dot/increment) in CVT. Factory Settings
120
0~240
Fast Scan Direction Regi Correction Value (2dot/increment) in CVT. Factory Settings
120
0~240
Fast Scan Direction Regi Correction Value (2dot/increment) in CVT. Factory Settings
February, 2008
6-33
General Procedures
IIT NVM List

Advertisement

Table of Contents
loading

This manual is also suitable for:

Workcentre 5225Workcentre 5230

Table of Contents