Tray5 (Bypass) Guide Adjustment
Purpose
This guide adjustment item is provided for the following purposes:
•
To check that size detection of the MPT Guide width detection is properly performed.
•
To set the sensor output values for the maximum and minimum positions for the MPT
Guide using NVM.
•
To display the detected size in the width direction of the MPT Guide.
Procedure
1.
Select Maintenance/Diagnostics
2.
Select Adjustment/Others.
3.
Select Tray5 (Bypass) Guide Adjustment.
4.
Set the MPT Guide on the machine at the minimum position.
5.
Select Minimum Size Position, then press the Start button.
6.
Result appears in Result column.
When "OK": The minimum position is set by the NVM.
When NG: Repeat the procedure.
7.
Set the MPT Guide on the machine at the maximum position.
8.
Select Maximum Position then press the Start button.
9.
Result appears in Result column.
When "OK": Set the value of the maximum position by the NVM.
When NG: Repeat the procedure.
10. Select Close].
General Procedures
Tray5 (Bypass) Guide Adjustment
UI Diagnostic
Mode.
February, 2008
6-120
Launch Version
WorkCentre 5225, 5230