Chain-
Link
Content
823-052
Paper Size for User Declare in Fax Proto-
col
825-001
1300Hz Receive ON/OFF
825-002
Boot Registration into Transmission Log
825-009
Pausing Time
825-017
Disconnection Detection for CH0
825-018
Disconnect Detection for Ch1
825-019
Disconnect Detection for Ch2
825-020
Disconnect Detection for Ch3
825-021
Disconnect Detection for Ch4
825-022
Disconnect Detection for Ch5
825-024
G4 to G3 Fallback Redial Enable/Disable
825-025
ZZF: Continuation Judge When Receiving
RTN
825-033
Time of Tone Detection before Dial (PBX)
825-046
PB Sending Level for Ch0
825-047
PB Sending Level for Ch1
825-048
PB Sending Level for Ch2
825-049
PB Sending Level for Ch3
825-050
PB Sending Level for Ch4
825-051
PB Sending Level for Ch5
825-052
PB Sending Level (High-Low (dB))for Ch0
825-053
PB Sending Level (High-Low (dB))for Ch1
825-054
PB Sending Level (High-Low (dB))for Ch2
825-055
PB Sending Level (High-Low (dB))for Ch3
825-056
PB Sending Level (High-Low (dB))for Ch4
825-057
PB Sending Level (High-Low (dB))for Ch5
825-058
Busy Tone Detection before Dial for Ch0
825-059
Busy Tone Detection before Dial for Ch1
825-060
Busy Tone Detection before Dial for Ch2
825-061
Busy Tone Detection before Dial for Ch3
825-062
Busy Tone Detection before Dial for Ch4
825-063
Busy Tone Detection before Dial for Ch5
General Procedures
Table 12 FAX Service
Default
Range
All paper sizes
1=ON (Receive)
0~1
0
0~1
60 (3 seconds)
0~240
1
0~1
1
0~1
1
0~1
1
0~1
1
0~1
1
0~1
0
0
4
6
0~15
6
0~15
6
0~15
6
0~15
6
0~15
6
0~15
0
0
0
0
0
0
0
0~1
0
0~1
0
0~1
0
0~1
0
0~1
0
0~1
February, 2008
6-100
Meaning
bit=0: No paper bit=1: Paper detected
bit10(0x00000400): A4LEF, bit11(0x00000800): A5LEF, bit14(0x00004000): B5LEF,
bit16(0x00010000): LetterSEF, bit25(0x02000000): A3SEF, bit26(0x04000000): A4SEF,
bit29(0x20000000): B4SEF
0=OFF (Do not receive), 1=ON (Receive)
0: Do not log, 1: Log
0 to 240 (12 seconds) (unit: 50 ms)
0: Do not detect disconnection, 1: Detect disconnection
0: Do not detect disconnection, 1: Detect disconnection
0: Do not detect disconnection, 1: Detect disconnection
0: Do not detect disconnection, 1: Detect disconnection
0: Do not detect disconnection, 1: Detect disconnection
0: Do not detect disconnection, 1: Detect disconnection
0 = Fallback Redial Off, 1= Fallback Redial On
0: Determine the fallback from the TCF check result and continue sending 1: Stop transmis-
sion (The document becomes eligible for resend)
0~255 (sec.)
0dBm (0) ~ -15 (15) dBm -1dBm increments
0dBm (0) ~ -15 (15) dBm -1dBm increments
0dBm (0) ~ -15 (15) dBm -1dBm increments
0dBm (0) ~ -15 (15) dBm -1dBm increments
0dBm (0) ~ -15 (15) dBm -1dBm increments
0dBm (0) ~ -15 (15) dBm -1dBm increments
High pass - Low pass (dB) 0: 2.0 1: 2.5 2: 3.0 3: 3.5 4: 4.0 5: 4.5 6: 5.0 7: 5.5 8: -2.0 9: -1.5
10: -1.0 11: -0.5 12: 0 13: 0.5 14: 1.0 15: 1.5
High pass - Low pass (dB) 0: 2.0 1: 2.5 2: 3.0 3: 3.5 4: 4.0 5: 4.5 6: 5.0 7: 5.5 8: -2.0 9: -1.5
10: -1.0 11: -0.5 12: 0 13: 0.5 14: 1.0 15: 1.5
High pass - Low pass (dB) 0: 2.0 1: 2.5 2: 3.0 3: 3.5 4: 4.0 5: 4.5 6: 5.0 7: 5.5 8: -2.0 9: -1.5
10: -1.0 11: -0.5 12: 0 13: 0.5 14: 1.0 15: 1.5
High pass - Low pass (dB) 0: 2.0 1: 2.5 2: 3.0 3: 3.5 4: 4.0 5: 4.5 6: 5.0 7: 5.5 8: -2.0 9: -1.5
10: -1.0 11: -0.5 12: 0 13: 0.5 14: 1.0 15: 1.5
High pass - Low pass (dB) 0: 2.0 1: 2.5 2: 3.0 3: 3.5 4: 4.0 5: 4.5 6: 5.0 7: 5.5 8: -2.0 9: -1.5
10: -1.0 11: -0.5 12: 0 13: 0.5 14: 1.0 15: 1.5
High pass - Low pass (dB) 0: 2.0 1: 2.5 2: 3.0 3: 3.5 4: 4.0 5: 4.5 6: 5.0 7: 5.5 8: -2.0 9: -1.5
10: -1.0 11: -0.5 12: 0 13: 0.5 14: 1.0 15: 1.5
0: Do not detect, 1: Detect
0: Do not detect, 1: Detect
0: Do not detect, 1: Detect
0: Do not detect, 1: Detect
0: Do not detect, 1: Detect
0: Do not detect, 1: Detect