Danfoss VLT Series Programming Manual page 378

Integrated servo drive isd 510 system
Hide thumbs Also See for VLT Series:
Table of Contents

Advertisement

Diagnostics
Code
Name
0x7182
Brake resistor power limit
0x7183
Brake chopper check failed
0x7380
External position sensor error Error
0xFF21
Internal fan fault
0xFF31
AUX Line 1 min off time
0xFF32
AUX Line 2 min off time
9
9
0xFF51
Internal error 1
0xFF52
Internal error 2
0xFF53
Internal error 3
0xFF54
Internal error 4
0xFF55
Internal error 5
0xFF56
Internal error 6
0xFF70
Firmware: Package description
mismatch
0xFF71
Firmware: Power cycle
needed
0xFF72
Firmware: Update started
Table 9.5 Error Codes for SAB
376
®
VLT
Integrated Servo Drive ISD
Severity
Description
(Warning/
error/trip
lock)
Error
Brake resistor power limit exceeded.
The power transmitted to the brake
resistor is calculated as an average
value over the last 120 s of run time.
The calculation is based on the DC-link
voltage and the brake resistor value set
in parameter 2-16 (Brake resistor power
120 s). The error is reported when the
value is exceeded within 120 s.
Error
Brake check failed. The brake resistor is
not connected or not working.
External encoder data could not be
read.
Warning
Internal fan fault. The fan warning
function checks if the fan is running/
mounted.
Warning
The minimum off time required to
protect the internal hardware has not
been met.
Warning
The minimum off time required to
protect the internal hardware has not
been met.
Trip lock
Internal error 1, contact Danfoss.
Trip lock
Internal error 2, contact Danfoss.
Trip lock
Internal error 3, contact Danfoss.
Trip lock
Internal error 4, contact Danfoss.
Trip lock
Internal error 5, contact Danfoss.
Trip lock
Internal error 6, contact Danfoss.
Trip lock
Firmware found does not match
package description.
Warning,
Firmware update transfer is completed
error
but a power cycle is required before
the new firmware is active.
Warning,
Firmware update in progress. The
error
warning becomes an error when an
attempt is made to enable the drive in
this state.
Danfoss A/S © 01/2017 All rights reserved.
®
510 System
LCP name
brake r pwr lim
brake ch check
ext sensor err
fan fault
AUX1 min off
AUX2 min off
PM int err 1
PM int err 2
PM int err 3
PM int err 4
PM int err 5
PM int err 6
FW pack err
need powercycle
FW update
MG36D102

Advertisement

Table of Contents

Troubleshooting

loading

Table of Contents