Servo Drive Parameter Descr...
7.22.9 Parameter 15-30: Error Code (0x603F)
This object provides the error code of the last error that occurred in the servo drive.
Attribute
Index
LCP parameter number
Name
Object code
Data type
Sub-index
Access
PDO mapping
Value range
Default value
7
7
Table 7.256 0x603F: Error Code
7.22.10 Parameter 16-92: Warning Code (0x5FFE)
This object provides the warning code of the last warning that occurred in the servo drive.
Attribute
Index
LCP parameter number
Name
Object code
Data type
Sub-index
Access
PDO mapping
Value range
Default value
Table 7.257 0x5FFE: Warning Code
7.22.11 Parameter: Control Source (0x5020)
This object defines the current control source.
0 means that the device is controlled via fieldbus (remote/PLC).
1 means that the device is controlled via LCP.
Attribute
Index
LCP parameter number
Name
Object code
Data type
Sub-index
Access
PDO mapping
Value range
352
®
VLT
Integrated Servo Drive ISD
Value
0x603F
15-30
Error code
Var
UNSIGNED16
0x00
Read only
Optional
See chapter 9.2.1 Troubleshooting
–
Value
0x5FFE
16-92
Warning code
Var
UNSIGNED16
0x00
Read only
Optional
See chapter 9.2.2 Error Codes
–
Value
0x5020
–
Control source
Var
UNSIGNED16
0x00
Read/write
Optional
0, 1
Danfoss A/S © 01/2017 All rights reserved.
®
510 System
MG36D102
Need help?
Do you have a question about the VLT Series and is the answer not in the manual?