Danfoss VLT Series Programming Manual page 377

Integrated servo drive isd 510 system
Hide thumbs Also See for VLT Series:
Table of Contents

Advertisement

Diagnostics
Code
Name
0x3293
U
low voltage
AUX
0x3294
U
undervoltage
AUX
0x3295
UDC high voltage
0x3296
UDC low voltage
0x4220
Too low temperature: Heat
sink
0x4290
Overtemperature: Heat sink
0x4291
Overtemperature: Control
card
0x4292
Overtemperature: SAB card
0x4293
Inrush overtemperature: SAB
card
0x4294
Inrush overtemperature:
power module
0x4410
Overtemperature: SAB
0x6320
Parameter error
0x6380
Configuration error
(parameter missing)
0x6381
Reinitialization of parameters
from power card
0x7111
Brake chopper short circuit
0x7181
Brake resistor failure
MG36D102
Programming Guide
Severity
Description
(Warning/
error/trip
lock)
Warning
U
below warning limit.
AUX
Error
U
below undervoltage limit.
AUX
Warning
The DC-link voltage (DC) is higher than
the high-voltage warning limit.
Warning
The DC-link voltage (DC) is lower than
the low-voltage warning limit.
Warning
Heat sink temperature low. The SAB is
too cold to operate. This warning is
based on the temperature sensor in
the IGBT module. This warning only
occurs when DC-link voltage is >250 V.
Warning,
The maximum temperature of the heat
Error
sink has been exceeded. The
temperature fault does not reset until
the temperature drops below a defined
heat sink temperature (115 °C).
Warning,
Control card overtemperature.
Error
The cutout temperature of the control
card is 80 °C.
Warning,
SAB card overtemperature.
Error
The cutout temperature of the SAB
card is 80 °C.
Error
Inrush fault. Too many transitions into
state Normal operation have occurred
within a short time period.
Error
Inrush fault. Too many power-ups have
occurred within a short time period.
Error
Logic OR of control card temperature
(see 0x4291) and/or heat sink
temperature (see 0x4290) and/or SAB
card temperature (see 0x4292).
Trip lock
A parameter has an invalid value.
Trip lock
A parameter is missing.
Trip lock
Configuration reinitialization.
Configuration parameter for power unit
has been reinitialized.
Error
The brake chopper is monitored during
operation. This error appears if a short
circuit occurs.
Error
The brake resistor is monitored during
operation. This error appears if a short
circuit occurs.
Danfoss A/S © 01/2017 All rights reserved.
LCP name
UAUX low volt
UAUX undervolt
UDC high volt
UDC low volt
low temp PM
overtemp PM
overtemp CC
overtemp SC
inrush SC
inrush PM
overtemp SAB
param err
config err
config reinit
brake ch short
brake r short
9
9