Danfoss VLT Series Programming Manual page 228

Integrated servo drive isd 510 system
Hide thumbs Also See for VLT Series:
Table of Contents

Advertisement

Programming
SAB_REF
BOOL
Enable
Illustration 6.93 DD_ReadDcLinkVoltage_SAB
Variable
Data
name
type
6
6
VAR_IN_OUT
Sab
SAB_REF
VAR_INPUT
Enable
BOOL
VAR_OUTPUT
Valid
BOOL
Busy
BOOL
Error
BOOL
ErrorInfo DD_ERROR_ISD51x
Voltage
INT
Table 6.79 DD_ReadDcLinkVoltage_SAB
6.5.8.11 DD_ReadParameter4_SAB
This function block asynchronously reads general objects
of up to 4 bytes from the object dictionary of the SAB if
the Enable input is set. For the index and the sub-index of
the parameters, see chapter 8 SAB Parameter Description.
The output data needs to be read from the device and is
therefore not immediately available.
226
VLT
DD_ReadDcLinkVoltage_SAB
Sab
Valid
Busy
Error
ErrorInfo
Voltage
Default
Description
value
Reference to the SAB.
See chapter 6.5.8.1 SAB_REF.
FALSE
Get the value of the parameter
continuously while enabled.
The function block has a valid
output.
The function block is not
finished and new output values
are to be expected.
An error has occurred within
the function block.
Error identification and instance
identifier.
See chapter 6.5.2.3 Error
Indication.
Value of the actual DC-link
voltage [V].
Danfoss A/S © 01/2017 All rights reserved.
®
Integrated Servo Drive ISD
SAB_REF
BOOL
BOOL
UINT
BOOL
USINT
BOOL
DD_ERROR_ISD51x
INT
Illustration 6.94 DD_ReadParameter4_SAB
Variable
name
VAR_IN_OUT
Sab
VAR_INPUT
Enable
Index
Subindex
VAR_OUTPUT
Valid
Busy
Error
ErrorInfo
AbortCode DWORD
Value
Table 6.80 DD_ReadParameter4_SAB
6.5.8.12 DD_ReadParameter_SAB
This function block asynchronously reads general objects
from the object dictionary of the SAB if the Enable input is
set. For the index and the sub-index of the parameters, see
chapter 8 SAB Parameter Description. The output data needs
to be read from the device and is therefore not available
immediately.
®
510 System
DD_ReadParameter4_SAB
Sab
Enable
Valid
Index
Busy
Subindex
Error
ErrorInfo
AbortCode
Value
Data
Default
Description
type
value
SAB_REF
Reference to the SAB.
See chapter 6.5.8.1 SAB_REF.
BOOL
FALSE
Get the value of the parameter
continuously while enabled.
UINT
0
Index of the object to be read.
USINT
0
Sub-index of the object to be
read.
BOOL
The function block has a valid
output.
BOOL
The function block is not
finished and new output
values are to be expected.
BOOL
An error has occurred within
the function block.
DD_ERROR_ISD51x
Error identification and
instance identifier.
See chapter 6.5.2.3 Error
Indication.
SDO abort code if there is an
error. Available in the list of
constants: SdoAbortCodes.
DWORD
Value of the specified
parameter.
BOOL
BOOL
BOOL
DD_ERROR_ISD51x
DWORD
DWORD
MG36D102