7.2.1.6 Controlword in Gear Mode

Table 7.17 shows the structure of the Controlword. Table 7.18 defines the values for the available synchronization modes (bits
5 and 6). Table 7.19 defines the values for bit 9 of the Controlword.
15
See Table 7.2
MSB
Table 7.17 Controlword in Gear Mode
Bit 6
0
0
1
1
7
7
Table 7.18 Definition of Bits 5 and 6 (Synchronization Modes)
Bit
9
Table 7.19 Definition of Bit 9

7.2.1.7 Controlword in ISD Inertia Measurement Mode

Table 7.17 shows the structure of the Controlword. A value of 1 in bit 4 starts the inertia measurement procedure. It must
remain high as long as the procedure is running, otherwise it is aborted. Table 7.21 defines the values for bits 4 and 8 of the
Controlword.
15
See Table 7.2
MSB
Table 7.20 Controlword in ISD Inertia Measurement Mode
Bit
4
8
Table 7.21 Definition of Bits 4 and 8

7.2.1.8 Controlword in Cyclic Synchronous Position Mode

The operation mode-specific bits and the Halt bit in the Controlword are ignored by the servo drive. The Halt function is
controlled by the control device.
236
VLT
10
9
8
Master sync
Reserved
direction
(0)
Bit 5
Definition
0
Synchronize shortest way.
1
Synchronize according to slow down mode.
0
Synchronize according to catch up mode.
1
Velocity-controlled synchronization (during gear in).
Value
Definition
0
Not relevant for synchronization mode 11;
For all other modes: Master start distance is in the positive direction of the guide value.
1
Not relevant for synchronization mode 11;
For all other modes: Master start distance is in the negative direction of the guide value.
1
9
8
0
Reserved (0)
Halt
Value
Definition
0
Do not start the measurement or stop an ongoing measurement.
1
Start measurement.
0
Enable bit 4.
1
Stop axis according to halt option code (see chapter 7.20.7 Parameter 50-47: Halt Option Code (0x605D)).
Danfoss A/S © 01/2017 All rights reserved.
®
Integrated Servo Drive ISD
7
6
See Table 7.2
Synchronization mode
7
6
5
See Table 7.2
Reserved (0)
®
510 System
5
4
Reserved
(0)
4
3
Measurement
See Table 7.2
start
3
0
See Table 7.2
LSB
0
LSB
MG36D102

Advertisement

Table of Contents

Troubleshooting

loading
Need help?

Need help?

Do you have a question about the VLT Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Table of Contents