7.22.7 Parameters 15-01 and 15-02: Total Running Time (0x5807)

The servo drive has 2 counters for the running time.
st
The 1
object is a non-resettable counter (32 bits). It contains the time in seconds that the servo drive has been running
(enabled). This means that the counter is running as long as the servo drive is in state Switched on, Operation enabled, or
Quick stop active.
nd
The 2
object contains the time in seconds that the servo drive has been running (enabled). This means that the counter is
running as long as the servo drive is in state Switched on, Operation enabled, or Quick stop active.
This 2
nd
counter is resettable by writing 0 to it, so it can be used to track service intervals.
Attribute
Index
Name
Object code
Data type
Sub-index
Description
Access
PDO mapping
Default value
Sub-index
LCP Parameter number
Description
350
®
VLT
Integrated Servo Drive ISD
Value
0x03
12-02
IP mask
UNSIGNED32
Read only
Yes
0x0000 0000–0xFFFF FFFF
0
0x04
12-03
IP gateway
UNSIGNED32
Read only
Yes
0x0000 0000–0xFFFF FFFF
0x08
12-04
Mac address
OCTET_STRING
Read only
Yes
Value
0x5807
Total running time
Array
UNSIGNED32
0x00
Value of highest sub-index
Read only
No
0x02
0x01
15-01
Total running time drive