Parameter 50-48: Shutdown Option Code (0X605B); Parameter 50-49: Disable Operation Option Code (0X605C) - Danfoss VLT Series Programming Manual

Integrated servo drive isd 510 system
Hide thumbs Also See for VLT Series:
Table of Contents

Advertisement

Servo Drive Parameter Descr...
Value
Definition
+1
Slow down with slow down ramp and remain in state Operation enabled.
+2
Slow down with quick stop ramp and remain in state Operation enabled.
+3
Slow down with current limit and remain in state Operation enabled.
Table 7.221 Definition of Values for Halt Option Code

7.20.8 Parameter 50-48: Shutdown Option Code (0x605B)

This object indicates what action is performed if a transition from state Operation enabled to state Ready to switch on occurs.
Attribute
Index
LCP parameter number
Name
Object code
Data type
Sub-index
Access
PDO mapping
Value range
Default value
Table 7.222 0x605B: Shutdown Option Code
Value
Definition
–1
Slow down with quick stop ramp; disable of the drive function.
0
Disable drive function (switch-off the drive power stage).
+1
Slow down with slow down ramp; disable of the drive function.
Table 7.223 Definition of Values for Shutdown Option Code
CAUTION
UNAUTHORIZED COMMAND
Using the value 0 for a servo drive with brake stops the servo drive immediately and may result in damage to the
holding brake.
Do not use the holding brake as active braking.
Change the shutdown option to -1.

7.20.9 Parameter 50-49: Disable Operation Option Code (0x605C)

This object indicates what action is performed if a transition from state Operation enabled to state Switched on occurs.
Attribute
Index
LCP parameter number
Name
Object code
Data type
Sub-index
Access
PDO mapping
MG36D102
Programming Guide
Value
0x605B
50-48
Shutdown option code
Var
INTEGER16
0x00
Read/write
Optional
See Table 7.223.
0
Value
0x605C
50-49
Disable operation option code
Var
INTEGER16
0x00
Read/write
Optional
Danfoss A/S © 01/2017 All rights reserved.
7
7
335