Danfoss VLT Series Programming Manual page 93

Integrated servo drive isd 510 system
Hide thumbs Also See for VLT Series:
Table of Contents

Advertisement

Servo Access Box (SAB) Oper...
Current
Transition
Required
state
command
condition
Fault
Reset errors No further
error
conditions
Table 3.1 States, Transitions, and Actions
NOTICE
If the U
input is not supplied on start-up, the state
AUX
machine only transitions to state U
the Enable U
control bit is set to 0 (active). If, at a later
AUX
stage, the U
input is provided, then the state machine
AUX
advances to state Standby.
3.2.1 Relay Outputs
The SAB has 2 relays:
Relay 1: 0x200D (see chapter 8.8 Object 0x200D:
Relay 1 Control).
Relay 2: 0x200E (see chapter 8.9 Object 0x200E:
Relay 2 Control).
Select the functionality of the relay via the corresponding
parameter (see Table 3.2). There is 1 parameter for each
relay for setting the On delay time and 1 for the Off delay
time. Both delay times are independently adjustable from
0 s (default) to 10 minutes and the adjustment is possible
in 1-second steps. The default setting for the relays is No
operation. The function of the on and off delay time is
described in Illustration 3.3.
MG36D102
Programming Guide
Executed
Following
action
state
Init
disabled, even if
AUX
Danfoss A/S © 01/2017 All rights reserved.
Event
Relay output
On
Delay
Event
Relay output
On
Delay
Event
Relay output
On
Delay
1 If the condition changes before the on or off delay times
expire, the relay is not affected.
Illustration 3.3 Relay Control Functions
Number
Description
0 (default)
No operation
1
SAB ready
2
SAB ready/remote control
3
SAB ready/local control
4
Enable/no warning
5
Alarm
6
Warning
7
Out of current range, U
8
Below current low, U
9
Above current high, U
10
Above current high, UDC
11
Encoder fault
12
Encoder simulation fault
13
Thermal warning
14
Thermal fault
15
Bus OK
16
Brake resistor ready, no warning
17
Brake resistor warning
18
Brake resistor ready, no fault
19
Brake resistor fault
20
Brake energy too high/fault (IGBT)
21
Controlword
22
Remote control
23
Local control
24
Standby/no alarm
25
Standby/no warning
O
Delay
1
O
Delay
AUX
AUX
AUX
91
3