Danfoss VLT Series Programming Manual page 97

Integrated servo drive isd 510 system
Hide thumbs Also See for VLT Series:
Table of Contents

Advertisement

Local Control Panel (LCP) O...
1
Status
24 V
38 °C
2.1 kW
2
A
565 V
4
6
Quick
Status
B
Menu
7
10
C
On
OK
15
Warn.
16
Alarm
17
Hand
D
O
On
18
19
Callout
Description
number
1
AUX line voltage
2
Temperature power card
3
Actual UDC (current)
4
ISD power consumption
5
Actual UDC (voltage)
Illustration 4.2 Display Area when Connected to the SAB
B. Display menu keys
Menu keys are used to access menus for parameter set-up,
toggling through status display modes during normal
operation, and viewing fault log data.
Callout
Key
Function
number
6
Status
Shows operational information.
7
Quick Menu Allows access to parameters.
8
Main Menu
Allows access to parameters.
9
Alarm Log
Shows the last 10 alarms.
Table 4.1 Display Menu Keys
MG36D102
Programming Guide
3
11.5 A
5
9
Main
Alarm
Menu
Log
8
11
12
13
Auto
Reset
On
14
20
21
Danfoss A/S © 01/2017 All rights reserved.
C. Navigation keys and indicator lights (LEDs)
Navigation keys are used to move the display cursor and
provide operation control in local operation. There are also
3 status LEDs in this area.
Callout
Key
Function
number
10
Back
Reverts to the previous step or list in
the menu structure.
11
Cancel
Cancels the last change or command
(unless the display mode is changed).
12
Info
Gives a definition of the current
function.
13
Navigation
The 4 keys enable navigation between
keys
menu items.
14
OK
Accesses parameter groups or enables
a selection.
Table 4.2 Navigation Keys
Callout
LED
Color
number
15
On
Green
16
Warn.
Yellow
17
Alarm
Red
Table 4.3 Indicator Lights (LEDs)
D. Operation keys and reset
The operation keys are at the bottom of the LCP.
Callout
Key
Function
number
18
Hand On
Enables the connected servo drive or
SAB to be controlled via the LCP. See
chapter 4.3.5 Hand On Mode for further
information.
Switching between Hand On mode and
Auto On mode is only possible in
certain states.
19
Off
Puts the SAB into state Standby and
the servo drive to state Switch on
Disabled.
This only works in Hand On mode.
Off mode enables transition from Hand
On mode to Auto On mode.
Function
The On LED activates when the
servo drive or SAB it is
connected to receives power
from the mains, auxiliary
supply, or a DC bus terminal.
When a warning is issued, the
yellow Warn. LED activates and
text appears in the display area
identifying the problem.
A fault condition causes the
red Alarm LED to flash and an
alarm text is shown.
95
4
4

Advertisement

Table of Contents

Troubleshooting

loading

Table of Contents