Subaru Legacy 2002 Service Manual page 2402

Hide thumbs Also See for Legacy 2002:
Table of Contents

Advertisement

DIAGNOSTICS CHART WITH SUBARU SELECT MONITOR
No.
23
CHECK SHIELD CIRCUIT.
1) Connect all connectors.
2) Measure resistance between shield con-
nector and chassis ground.
Connector & terminal
DTC 22 / (B62) No. A5 — Chassis
ground:
DTC 24 / (B62) No. A6 — Chassis
ground:
NOTE:
For the DTC 26 and 28:
Go to step 24.
24
CHECK ABSCM&H/U.
1) Connect all connectors.
2) Erase the memory.
3) Perform inspection mode.
4) Read out the DTC.
25
CHECK ANY OTHER DTC APPEARANCE.
Step
Is the resistance less than
0.5 Ω?
Is the same DTC as in the
current diagnosis still being
output?
Are other DTC being out-
put?
ABS-101
Check
Yes
Go to step 24.
Replace
ABSCM&H/U.
<Ref. to ABS-6,
ABS Control Mod-
ule and Hydraulic
Control Unit
(ABSCM&H/U).>
Proceed with the
diagnosis corre-
sponding to the
DTC.
ABS (Diagnostics)
No
Repair shield har-
ness.
Go to step 25.
A temporary noise
interference.

Advertisement