HVAC System (Heater, Ventilator and A/C)
3. Refrigerant Recovery
Procedure
S701291
A: OPERATION
CAUTION:
¼ During operation, be sure to wear safety
goggles and protective gloves.
¼ Connect the refrigerant recovery system
with the manifold gauge set to discharge the
refrigerant from the A/C system and reuse it.
¼ When reusing the discharged refrigerant,
keep service cans on hand. Because the dis-
charge rate with the recovery system is approx.
90%, service cans are necessary to charge the
refrigerant.
¼ Follow the detailed operation procedure
described in the operation manual attached to
the refrigerant recovery system.
1) Perform the compressor oil return operation.
<Ref. to 28, OPERATION, Compressor Oil.>
2) Stop the engine.
3) Close the valves on the low-/high-pressure
sides of the manifold gauge set.
4) Install the low-/high-pressure hoses to the ser-
vice ports on the low-/high-pressure sides of the
vehicle respectively.
5) Connect the center hose to the refrigerant
recovery system.
6) Follow the operation manual to activate the
refrigerant recovery system.
REFRIGERANT RECOVERY PROCEDURE
S701291A16
G4M0585
G4M0586
AC-22