ALEOS 4.9.0 Software Configuration User Guide for AirLink RV50 Series
Table D-10: Serial AT Commands
Command
*HOSTMODE?
MD
MLIST
Rev 1 Dec. 17
Description
Query the current host mode.
AT*HOSTMODE? returns:
AT
PPP
TCP
UDP
Note: If the device is not in AT mode, Telnet into the device to execute this command.
Query or set the default start-up mode for the serial port. When the device is power-
cycled, the serial port enters the mode specified by this command after 5 seconds.
On startup, typing ATMD0 within 5 seconds changes the mode to normal (AT
command) mode.
ATMD? to query
ATMD<hh> (hex byte) to set
<hh>=00—Normal (AT Command mode)
<hh>=02—PPP
<hh>=03—UDP
<hh>=04—TCP
<hh>=08—reverse telnet/ssh
<hh>=13—Modbus ASCII
<hh>=23—Modbus RTU (Binary)
<hh>=33—BSAP
<hh>=63—Variable Modbus
<hh>=83—UDP Multiple Unicast
Add IP addresses to the Modbus address list or query the Modbus address list,
using decimal index values.
Format is MLISTIndex(decimal)=IP address
Example: ATMLIST10=123.123.123.123, where:
10 is the Index
123.123.123.123 is the IP address
MLISTIndex=IP to add an IP address to the list
Including the port number after the IP address is optional. If you include the port
number, separate the port number and IP address by a colon.
For example: 10=123.123.123.123:11223
MLIST? to query the Modbus address list; returns the addresses in the list in the
format Index=IP.
For example:
10=123.123.123.123
11=124.124.124.124
12=125.125.125.125
13=126.126.126.126
Range for index numbers is 0–65535. The Modbus address list accepts up to 100
entries.