Sierra Wireless AirLink RV50 Series User Manual page 175

Hide thumbs Also See for AirLink RV50 Series:
Table of Contents

Advertisement

Field
Standby Voltage (100
milliVolts)
Standby Qualification
Period (seconds)
Resume immediately
at Voltage
(100 milliVolts)
Standby
Use Standby Mode
Rev 1 Dec. 17
Description
If the incoming voltage to the gateway is below the value set in this field for the period of
time set in the
Standby Qualification Period (seconds)
mode.
This field is read-only if the
Voltage Standby Mode
is set to Custom, the valid range is:
58–294 hundreds of milliVolts
Default value depends on the setting in the Low Voltage Standby Mode field. See
Table
8-1.
Enter the value in tenths of Volts. For example, for 11.5 V, enter 115.
The difference between the number in the Standby Voltage field and the number in the
Resume immediately at Voltage (100 milliVolts)
smaller number in the Low Voltage Standby Mode field. For example, if you enter 120 in the
Resume immediately at Voltage field, the highest number you can enter in the Low Voltage
Standby mode field is 114.
Set the time period (in seconds) that the voltage to the gateway is below the value set in
the
Standby Voltage (100 milliVolts)
This field is read-only if the
Voltage Standby Mode
is set to Custom, the valid range is:
30–3600 seconds
Default is 30.
Set the voltage at which the gateway exits standby mode and resumes normal operation.
This field is read-only if the
Voltage Standby Mode
is set to Custom, the valid range is:
68–300 hundreds of milliVolts
Default value depends on the setting in the Low Voltage Standby Mode field. See
Table
8-1.
Enter the value in tenths of Volts. For example, for 12.5 V, enter 125.
The difference between the number in the
number in the Resume immediately at Voltage field must be greater than 5, with the smaller
number in the Low Voltage Standby Mode field. For example, if you enter 120 in the
Resume immediately at Voltage field, the highest number you can enter in the Low Voltage
Standby mode field is 114.
Select the type of Standby mode you want to configure
Options are:
Disable (default)
Timed
I/O
I/O + Timed
Changes take effect when you click Apply. No reboot is required.
Note: You cannot set this field to I/O or I/O + Timed if the I/O line is already being used by
the
Relay Output
or by the
175
Low Voltage Standby Mode
field must be greater than 5, with the
field before the gateway goes into standby mode.
Low Voltage Standby Mode
Low Voltage Standby Mode
Standby Voltage (100 milliVolts)
Pull-up for
I/O.
Services Configuration
field, the gateway goes into standby
is set to Automatic or Off. If
is set to Automatic or Off. If
is set to Automatic or Off. If
field and the
Low
Low
Low
41111088

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents