Field
HTTP Server
And ACEview
Services
LWM2M
Keep Alive
Interval
(seconds)
Always Register
on Startup
AAF
M3DA Protocol
Password
Manual
Connection
Status
Connect
Rev 1 Dec. 17
Description
Allows you to activate the:
MSCI server—enables you to configure the gateway remotely using MSCI over
HTTP
ACEview service—enables the gateway to communicate with the ACEview
Windows utility
Options are:
Disable—Both services are disabled.
LAN Only—The MSCI HTTP server and ACEview service are only accessible
through a LAN connection. (Default)
Both WAN And LAN—The MSCI HTTP server and ACEview service are acces-
sible through both WAN and LAN connections.
Note: In order to use MSCI server initiated communication from ALMS, HTTP
Server And ACEview Services must be set to Both WAN And LAN.
Use this field to configure how frequently the gateway pings ALMS to confirm an IP
connection. Options are:
1–3600
0—Disabled (Default)
Use this field to set the gateway's registration behavior on startup:
Disable—The gateway performs a registration update. It signals ALMS that it is
up and running and refreshes its registration. A registration update consumes
far less bandwidth than a registration. (Default)
Enable—The gateway performs a LWM2M registration on startup. The gateway
declares its capabilities to ALMS and synchronizes its configuration.
M3DA Protocol Password
This password must be configured on the AirLink device and on ALMS. The default
password is 12345.
Displays the current manual connection status.
The Connect button enables you to manually connect an AirLink device to ALMS.
This may be useful for troubleshooting the connection between the platform and the
remote device and confirming that AAF scripts or jobs created are executing as
expected on ALMS.