ALEOS 4.9.0 Software Configuration User Guide for AirLink RV50 Series
Field
I/O + Timed
To configure the fields for I/O + Timed, see
When both I/O and Timed are configured, the gateway is standby mode only when both I/O and Timed conditions for
standby mode are met. The gateway exits standby and returns to the normal operating mode when either the Timed or
I/O (or both) conditions for standby are no longer met.
Example: The following example is based on the default settings.
Timed is set to wake at 10 minutes after the hour and return to standby 50 minutes after the hour.
I/O is set to wake when the I/O is high.
Timed
1:10
1:50 2:10
I/O
Gateway power mode
Rev 1 Dec. 17
Description
Timed
on page 176 and
2:50 3:10
3:50 4:10
178
I/O
on page 176.
4:50 5:10
Time
I/O High
I/O Low
Wake
Standby
Wake
Standby
(Wake)
(Standby)