Sierra Wireless AirLink RV50 Series User Manual page 272

Hide thumbs Also See for AirLink RV50 Series:
Table of Contents

Advertisement

ALEOS 4.9.0 Software Configuration User Guide for AirLink RV50 Series
Table 11-2: Serial Port Configuration > Advanced
Field
Quiet Mode
AT Verbose Mode
Call Progress Result
Mode
Convert 12 digit
Number to IP Address
Disable ATZ Reset
IP List Dial
Keep Alive Mode
Keep Alive Delay
(minutes)
Rev 1 Dec. 17
Description
Disable or enable display of device responses. Options are:
Disable (default)
Enable
You can also use an AT command to configure this field. See
Sets the level of information returned for AT commands
Options are:
Verbose (default)
Numeric
You can also use an AT command to configure this field. See
When enabled adds 19200 to CONNECT messages
Options are:
Disable (default)
Enable
You can also use an AT command to configure this field. See
Choose whether a 12-digit number is converted to an IP address (eg. 111222333444 to
111.222.333.444). Options are:
Use as Name (default)
Use as IP
You can also use an AT command to configure this field. See
The value set in this field determines whether or not issuing an ATZ Command resets the
AirLink gateway. Options are:
On: Block is enabled—ATZ does not reset the device.
Off: Block is disabled—ATZ resets the device. (default)
You can also use an AT command to configure this field. See
This allows access to the Modbus IP Address using the first two digits of the dial string. For
example, ATDT1234567 would imply ID index 12 on the Modbus Address list and use the
associated IP Address as the destination. Options are:
Disable (default)
Enable
You can also use an AT command to configure this field. See
When this feature is enabled, the AirLink gateway reboots if there is no traffic for longer
than the period configured in the Keep Alive Delay field. Options are"
Disable (default)
Enable
When Keep Alive Mode is enabled, use this field to set the delay (in minutes) before the
AirLink gateway reboots if there is no traffic on the serial port. Accepted values:
10–65535 (Default is 10.)
272
Q
on page 461.
V
on page 463.
X
on page 463.
*NUMTOIP
on page 456
*DATZ
on page 460.
IPL
on page 456.
41111088

Hide quick links:

Advertisement

Table of Contents
loading