5.11 Graphic Controller Automation; General Patch - Studer D950 Operating Instructions Manual

Sw v 3.3
Table of Contents

Advertisement

5.11 Graphic Controller Automation

Automated Items:
5.11.1

General Patch

Connection Behavior:
Date printed: 27.08.03
As discussed in the Switch Automation chapter, controls that are defined
in the VMC may be automated. While most of these controls are work sur-
face oriented, some controls are found only in the Graphic Controller.
Automatable items in the Graphic Controller are as follows:
• General Patch Connections
• Channel Patch:
-
Input Selector
-
Processor Block Order
-
Dynamic Sidechain Link Setup
-
Dynamic Sidechain Link Enable
-
Dynamic Key Input Routing
-
Direct Output Tap Location
-
Meter Feed Tap Location
Connections within the General Patch may be automated. Both "Make
Connection" and "Break Connection" operations may be stored as Static
objects or recorded as Dynamic objects. All types of General Patch con-
nections may be recorded.
The General Patch does not have dedicated automation controls. The cur-
rent global automation modes apply to the General Patch. The SW / SWIT
Pre-Selector must be used to select global modes.
General Patch connections follow the rules of a Press and Release switch
operation. Refer to
chapter
SW V3.3
D950/Vista7 Digital Mixing System
5.10.3.1.
AutoTouch+ 5-95