Studer D950 Operating Instructions Manual page 538

Sw v 3.3
Table of Contents

Advertisement

D950 Digital Mixing System
// number of available ports for 9pin (RS422) machine control. "1" means 9Pin control without
// Colin Broad SR3 controller, "4" means a Colin Broad SR3 installed.
// "0" means 9Pin interface not available.
RS422Ports=1
// defines the first available port on a Colin Broad controller. "2" means port A is
// reserved for communication of the CB SR3 controller with D950.
RS422First=1
// Paddle Ready Only. "Yes" means Pec/Dir panel gives no record strobe on the REC paddle switch.
// "No" means Pec/Dir panel adds a record strobe on the paddle switch.
PADDLE_RDY_ONLY=Yes
// display of the rec-ready (armed) state on the REC paddle switch. "Yes" means the record paddle
// is lit if the track is ready or recording. "No" means the record paddle is lit only if the
// track is recording.
PADDLE_DISP_RDY=No
// save at stop for systems with Pec/direct panel installed. "Yes" disarms all armed tracks
// assigned to stems when stop is pressed on either the D950 AutoTouch panel
// or the D950 function keys.
RS422SaveAtStop=Yes
; Syntax: single letters indicate the kind of devices connected to a port
; put square or curly brackets around them
;
{t}:time code port -> port number 2
;
{a}:audio - port with analog audio devices (monitoring)
;
{p}:panels; polling (monitoring)
;
{d}:d19 (MicAds / RS422 controlled equipment)
;
{9}:Sony 9 Pin interface
;
{w}:PCAnywhere -> use port number < 10
;
{c}:PWRChute
;
{n}:not used
[d950SerialPorts]
1= {t} COM2 baud=38400 parity=N data=8 stop=1
2= {p} COM5 baud=115200 parity=N data=8 stop=1
3= {a} COM6 baud=115200 parity=N data=8 stop=1
4= {d} COM7 baud=38400 parity=N data=8 stop=1
5= {n} COM8 baud=115200 parity=N data=8 stop=1
6= {c} COM9 baud=2400 parity=N data=8 stop=1
7= {n} COM10 baud=115200 parity=N data=8 stop=1
8= {n} COM11 baud=115200 parity=N data=8 stop=1
9= {w} COM12 baud=19200 parity=N data=8 stop=1
Keywords:
6-8 System Administration
IsUS=Yes/No
Enable/disable the standard Windows close function in the upper right cor-
ner.
NetIsUsed=Yes/No
If the control threads are distributed on several different PCs, and the
D950system.exe is running on each of them, the processes communicate
via WINDOWS sockets and Fast Ethernet. If all control threads run on the
same PC in one D950system.exe, there is no need to communicate over a
network. A thread-to-thread communication via standard thread messages
is used instead of sockets. However the API will remain the same for using
sockets or standard thread messages.
HTTPIsUsed=Yes/No
HTTP server is active/inactive for remote control via Netscape.
IsAutoActive=Yes/No
The Automation threads should be started.